32 research outputs found

    The Effect of Ear Canal Orientation on Tympanic Membrane Motion and the Sound Field Near the Tympanic Membrane

    Get PDF
    The contribution of human ear canal orientation to tympanic membrane (TM) surface motion and sound pressure distribution near the TM surface is investigated by using an artificial ear canal (aEC) similar in dimensions to the natural human ear canal. The aEC replaced the bony ear canal of cadaveric human temporal bones. The radial orientation of the aEC relative to the manubrium of the TM was varied. Tones of 0.2 to 18.4 kHz delivered through the aEC induced surface motions of the TM that were quantified using stroboscopic holography; the distribution of sound in the plane of the tympanic ring PTR was measured with a probe tube microphone. The results suggest that the ear canal orientation has no substantial effect on TM surface motions, but PTR at frequencies above 10 kHz is influenced by the ear canal orientation. The complex TM surface motion patterns observed at frequencies above a few kilohertz are not correlated with simpler variations in PTR distribution at the same frequencies, suggesting that the complex sound-induced TM motions are more related to the TM mechanical properties, shape, and boundary conditions rather than to spatial variations in the acoustic stimulus.National Institute on Deafness and Other Communication Disorders (U.S.) (Grants NRSA 1F32DC009949-01, 1R03DC011617-01, and R01-DC008642)Lakshmi Mitta

    A bone-thickness map as a guide for bone-anchored port implantation surgery in the temporal bone

    Get PDF
    The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant’s location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map (n = 10) with conventional surgery without assistance (n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and OPEN ACCESS Materials 2013, 6 5292 suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient’s safety during BAP surgery in the temporal bone

    Study of a Quantum Hall effect in exfoliated graphene towards an application in quantum metrology

    No full text
    L’effet Hall quantique (EHQ), observé par exemple dans des gaz bidimensionnels d’électrons (2DEGS) à basse température et sous fort champ magnétique, a révolutionné la métrologie des résistances car il permet d’obtenir un étalon quantique de résistance qui ne dépend que de e et h (respectivement la charge de l’électron et la constante de Planck). Une des missions des métrologues est de développer les étalons en améliorant leurs performances ou en les rendant plus facile à mettre en oeuvre (travaillant à plus haute température ou plus faible champ magnétique). Dans ce contexte, la physique du graphène suscite l’intérêt pour une application en métrologie. Une monocouche de graphène est une feuille d’un seul atome d’épaisseur constituée d’atomes de carbone disposés en nid d’abeille. Une bicouche de graphène est formée par empilement de deux monocouches. Les écarts en énergie entre les premiers niveaux de Landau dans la monocouche et dans la bicouche sont supérieurs par rapport à ceux dans GaAs ce qui rend l’EHQ dans le graphène plus robuste et laisse envisager le développement d’un étalon plus pratique. Durant ma thèse, nous avons mis en place un protocole de fabrication de barres de Hall en graphène exfolié comprenant un repérage optique, des lithographies électroniques, la métallisation, la gravure plasma… L’utilisation de substrat de silicium oxydé en surface rend possible l’utilisation d’une grille en face arrière. En outre la géométrie des échantillons répond au mieux aux critères métrologiques (canal central large, prises de tension bien définies, …). A basse température, le dopage résiduel obtenu après le recuit in situ est de l’ordre de 3-4x1011 cm-2. Les mobilités sont proches de 3000 cm2/(V.s) et 4000 cm2/(V.s) respectivement pour les échantillons monocouche et bicouche à la fois pour les électrons et les trous. Le transport mésoscopique a été caractérisé à basse température par des mesures de localisation faible et de fluctuations universelles de conductance. La longueur de cohérence que nous avons extraite est de l’ordre de 0.5 µm à 1.5 K. La résistance des contacts mesurée en régime d’EHQ est plutôt faible (typiquement quelques ohms). L’EHQ a été étudié en détail à basse température (300 mK < T <1.5 K) et sous fort champ magnétique (jusqu’à 18.5T) à la fois dans la monocouche et la bicouche en mesurant de manière précise la résistance de Hall (RH) et la résistance longitudinale (Rxx). Les mesures fines de RH sont réalisées à l’aide d’un pont de comparaison basé sur un Comparateur Cryogénique de Courant ; elles consistent à comparer indirectement l’EHQ dans l’échantillon de graphène à l’EHQ obtenu dans une barre de Hall en GaAs/AlGaAs qui est supposée fournir la valeur exacte RH/2. Nos mesures révèlent un accord entre la résistance de Hall dans le graphène et la valeur attendue avec une incertitude de quelques 10-7. Au plus faible courant et dans l’état de dissipation minimale (Rxx→0), nous avons obtenu un accord avec une incertitude relative de 3.10-7. Ce niveau de précision est principalement limité par la petite taille de nos échantillons et par les inhomogénéités de la densité qui y sont présents, ces deux caractéristiques amenant de faibles courants de rupture de l’EHQ (1-2 µA). Toutefois, nos résultats sont à ce jour les tests les plus précis concernant l’EHQ dans du graphène exfolié et les premiers tests sur une bicouche. Ils confirment le potentiel de l’EHQ dans le graphène pour une application en métrologie.The quantum Hall effect (QHE) observed in two dimensional electron gases (2DEGs) at low temperature and under high magnetic induction, has revolutionized the resistance metrology because it leads to a universal and very reproducible quantum resistance standard only dependent on e and h (respectively the electron charge and Planck's constant). One of the metrologists' missions is to develop standards with improved performances and to notably make them more practical, working for example at higher temperature or lower magnetic induction. In this context, graphene physics could be very interesting for metrological applications. Monolayer graphene is a one atom thick layer of carbon atoms condensed in a honeycomb lattice. A bilayer graphene consists in two stacked monolayers. Larger energy spacings between the first Landau Levels in monolayer and in bilayer than in GaAs make the QHE in graphene more robust and give hope that more practical standards could be developed. During the PhD, we have set a protocol up in order to fabricate exfoliated graphene based Hall bars, including location with an optical microscope, e-beam lithography, metallization, plasma etching… Backgated using oxidized silicon wafers the devices were designed to fulfill at best the metrological requirements (large conduction channel, well defined voltage probes…). At low temperature, the typical charge carrier residual doping obtained after the annealing process was 3-4x1011 cm-2. Mobilities were close to 3000 cm2/(V.s) and 4000 cm2/(V.s) respectively for the monolayer and the bilayer based device both for holes and electrons. Mesoscopic transport was characterized at low temperature by weak localization and universal conductance fluctuations (UCF) measurements. The phase coherence length deduced was about 0.5 µm below 1.5 K. The resistance of the contacts, measured in the QHE regime, appeared to be rather low (typically few ohms). The QHE was investigated in details at low temperature (300 mK < T <1.5 K) and high magnetic field (up to 18.5 T) in both monolayer and bilayer graphene by refined measurements of the Hall resistance (RH) and also of the longitudinal resistance (Rxx). The accurate measurements of RH were performed using a Cryogenic Current Comparator based resistance bridge. They consist in an indirect comparison between the QHE in graphene and the QHE obtained in a GaAs based Hall bar, supposed to deliver the expected value RH/2. Our measurements showed an agreement of the Hall resistance in graphene with the expected value within some parts in 107. At the lowest biasing current and in the lowest dissipation state (where Rxx→0) it is possible to demonstrate an agreement within an uncertainty of 3 parts in 107. That accuracy is essentially limited by the small size, and the poor homogeneity of the carrier density of the graphene electronic systems, both acting for a very reduced breakdown current of the QHE (1-2 µA). Nevertheless these results are the most accurate tests of the QHE performed in exfoliated graphene and the first universality test of the QHE with bilayer graphene. They confirm the potential of the QHE in graphene for the metrological application

    Forecasting respiratory rate in sedated patients with partial least squares regression

    No full text
    Remifentanil, like the other sedative drugs used to achieve conscious sedation, has an impact on the efficiency of patient ventilation. Since the quality of breathing has an indirect effect on blood O2 and CO2 concentrations, keeping patients' blood homeostasis relies on anesthetists' and nurses' vigilence. The current state of patient monitoring during conscious sedation can detect unsuccessful respirations only after they have occurred. Hence, there is a clinical need for a signal classifier to predict potential respiration failure in sedated patients. Given that the physiological changes involved in this context are transitory, and that opioids affect the Central Nervous System, the hypothesis is that opioids' effect on a patient drive to breath will result in detectable changes in electrocardiogram and capnogram signals. The purpose of this project is to design a signal classiffier to predict respiratory rate (RR) based on the analysis of the ECG spectrum and capnogram shape. Using patient audit data, a modeling set was created. Power Spectral Density calculation on a sliding Hamming window was the feature extraction used on ECG. A custom filter was designed to extract values describing the shape of each breaths in terms of slope, curvature and integral of the capnographic trace. Both patient specific (single user) and robust (mulit-user) solution were investigated. PLS regression resulted in parsimonious patient specific models capable of predicting the respiratory rate with an average accuracy of 90%. The performance, however, dropped for low RR. The analysis of the weights showed that the frequencies under 7.5Hz contain the majority of the information. Several limitations are addressed in the building of a robust multi-user model. The results obtained suggest an existing patient-specific correlation between the frequency content of ECG and the upcoming RR. Further investigation is required to achieve clinically useful predictio

    Etude de l'effet Hall quantique dans le graphène exfolié en vue d'une application en métrologie quantique

    Get PDF
    The quantum Hall effect (QHE) observed in two dimensional electron gases (2DEGs) at low temperature and under high magnetic induction, has revolutionized the resistance metrology because it leads to a universal and very reproducible quantum resistance standard only dependent on e and h (respectively the electron charge and Planck's constant). One of the metrologists' missions is to develop standards with improved performances and to notably make them more practical, working for example at higher temperature or lower magnetic induction. In this context, graphene physics could be very interesting for metrological applications. Monolayer graphene is a one atom thick layer of carbon atoms condensed in a honeycomb lattice. A bilayer graphene consists in two stacked monolayers. Larger energy spacings between the first Landau Levels in monolayer and in bilayer than in GaAs make the QHE in graphene more robust and give hope that more practical standards could be developed. During the PhD, we have set a protocol up in order to fabricate exfoliated graphene based Hall bars, including location with an optical microscope, e-beam lithography, metallization, plasma etching… Backgated using oxidized silicon wafers the devices were designed to fulfill at best the metrological requirements (large conduction channel, well defined voltage probes…). At low temperature, the typical charge carrier residual doping obtained after the annealing process was 3-4x1011 cm-2. Mobilities were close to 3000 cm2/(V.s) and 4000 cm2/(V.s) respectively for the monolayer and the bilayer based device both for holes and electrons. Mesoscopic transport was characterized at low temperature by weak localization and universal conductance fluctuations (UCF) measurements. The phase coherence length deduced was about 0.5 µm below 1.5 K. The resistance of the contacts, measured in the QHE regime, appeared to be rather low (typically few ohms). The QHE was investigated in details at low temperature (300 mK < T <1.5 K) and high magnetic field (up to 18.5 T) in both monolayer and bilayer graphene by refined measurements of the Hall resistance (RH) and also of the longitudinal resistance (Rxx). The accurate measurements of RH were performed using a Cryogenic Current Comparator based resistance bridge. They consist in an indirect comparison between the QHE in graphene and the QHE obtained in a GaAs based Hall bar, supposed to deliver the expected value RH/2. Our measurements showed an agreement of the Hall resistance in graphene with the expected value within some parts in 107. At the lowest biasing current and in the lowest dissipation state (where Rxx→0) it is possible to demonstrate an agreement within an uncertainty of 3 parts in 107. That accuracy is essentially limited by the small size, and the poor homogeneity of the carrier density of the graphene electronic systems, both acting for a very reduced breakdown current of the QHE (1-2 µA). Nevertheless these results are the most accurate tests of the QHE performed in exfoliated graphene and the first universality test of the QHE with bilayer graphene. They confirm the potential of the QHE in graphene for the metrological application.L’effet Hall quantique (EHQ), observé par exemple dans des gaz bidimensionnels d’électrons (2DEGS) à basse température et sous fort champ magnétique, a révolutionné la métrologie des résistances car il permet d’obtenir un étalon quantique de résistance qui ne dépend que de e et h (respectivement la charge de l’électron et la constante de Planck). Une des missions des métrologues est de développer les étalons en améliorant leurs performances ou en les rendant plus facile à mettre en oeuvre (travaillant à plus haute température ou plus faible champ magnétique). Dans ce contexte, la physique du graphène suscite l’intérêt pour une application en métrologie. Une monocouche de graphène est une feuille d’un seul atome d’épaisseur constituée d’atomes de carbone disposés en nid d’abeille. Une bicouche de graphène est formée par empilement de deux monocouches. Les écarts en énergie entre les premiers niveaux de Landau dans la monocouche et dans la bicouche sont supérieurs par rapport à ceux dans GaAs ce qui rend l’EHQ dans le graphène plus robuste et laisse envisager le développement d’un étalon plus pratique. Durant ma thèse, nous avons mis en place un protocole de fabrication de barres de Hall en graphène exfolié comprenant un repérage optique, des lithographies électroniques, la métallisation, la gravure plasma… L’utilisation de substrat de silicium oxydé en surface rend possible l’utilisation d’une grille en face arrière. En outre la géométrie des échantillons répond au mieux aux critères métrologiques (canal central large, prises de tension bien définies, …). A basse température, le dopage résiduel obtenu après le recuit in situ est de l’ordre de 3-4x1011 cm-2. Les mobilités sont proches de 3000 cm2/(V.s) et 4000 cm2/(V.s) respectivement pour les échantillons monocouche et bicouche à la fois pour les électrons et les trous. Le transport mésoscopique a été caractérisé à basse température par des mesures de localisation faible et de fluctuations universelles de conductance. La longueur de cohérence que nous avons extraite est de l’ordre de 0.5 µm à 1.5 K. La résistance des contacts mesurée en régime d’EHQ est plutôt faible (typiquement quelques ohms). L’EHQ a été étudié en détail à basse température (300 mK < T <1.5 K) et sous fort champ magnétique (jusqu’à 18.5T) à la fois dans la monocouche et la bicouche en mesurant de manière précise la résistance de Hall (RH) et la résistance longitudinale (Rxx). Les mesures fines de RH sont réalisées à l’aide d’un pont de comparaison basé sur un Comparateur Cryogénique de Courant ; elles consistent à comparer indirectement l’EHQ dans l’échantillon de graphène à l’EHQ obtenu dans une barre de Hall en GaAs/AlGaAs qui est supposée fournir la valeur exacte RH/2. Nos mesures révèlent un accord entre la résistance de Hall dans le graphène et la valeur attendue avec une incertitude de quelques 10-7. Au plus faible courant et dans l’état de dissipation minimale (Rxx→0), nous avons obtenu un accord avec une incertitude relative de 3.10-7. Ce niveau de précision est principalement limité par la petite taille de nos échantillons et par les inhomogénéités de la densité qui y sont présents, ces deux caractéristiques amenant de faibles courants de rupture de l’EHQ (1-2 µA). Toutefois, nos résultats sont à ce jour les tests les plus précis concernant l’EHQ dans du graphène exfolié et les premiers tests sur une bicouche. Ils confirment le potentiel de l’EHQ dans le graphène pour une application en métrologie

    Etude de l'effet Hall quantique dans le graphène exfolié en vue d'une application en métrologie quantique

    No full text
    L effet Hall quantique (EHQ), observé par exemple dans des gaz bidimensionnels d électrons (2DEGS) à basse température et sous fort champ magnétique, a révolutionné la métrologie des résistances car il permet d obtenir un étalon quantique de résistance qui ne dépend que de e et h (respectivement la charge de l électron et la constante de Planck). Une des missions des métrologues est de développer les étalons en améliorant leurs performances ou en les rendant plus facile à mettre en oeuvre (travaillant à plus haute température ou plus faible champ magnétique). Dans ce contexte, la physique du graphène suscite l intérêt pour une application en métrologie. Une monocouche de graphène est une feuille d un seul atome d épaisseur constituée d atomes de carbone disposés en nid d abeille. Une bicouche de graphène est formée par empilement de deux monocouches. Les écarts en énergie entre les premiers niveaux de Landau dans la monocouche et dans la bicouche sont supérieurs par rapport à ceux dans GaAs ce qui rend l EHQ dans le graphène plus robuste et laisse envisager le développement d un étalon plus pratique. Durant ma thèse, nous avons mis en place un protocole de fabrication de barres de Hall en graphène exfolié comprenant un repérage optique, des lithographies électroniques, la métallisation, la gravure plasma L utilisation de substrat de silicium oxydé en surface rend possible l utilisation d une grille en face arrière. En outre la géométrie des échantillons répond au mieux aux critères métrologiques (canal central large, prises de tension bien définies, ). A basse température, le dopage résiduel obtenu après le recuit in situ est de l ordre de 3-4x1011 cm-2. Les mobilités sont proches de 3000 cm2/(V.s) et 4000 cm2/(V.s) respectivement pour les échantillons monocouche et bicouche à la fois pour les électrons et les trous. Le transport mésoscopique a été caractérisé à basse température par des mesures de localisation faible et de fluctuations universelles de conductance. La longueur de cohérence que nous avons extraite est de l ordre de 0.5 m à 1.5 K. La résistance des contacts mesurée en régime d EHQ est plutôt faible (typiquement quelques ohms). L EHQ a été étudié en détail à basse température (300 mK 0), nous avons obtenu un accord avec une incertitude relative de 3.10-7. Ce niveau de précision est principalement limité par la petite taille de nos échantillons et par les inhomogénéités de la densité qui y sont présents, ces deux caractéristiques amenant de faibles courants de rupture de l EHQ (1-2 A). Toutefois, nos résultats sont à ce jour les tests les plus précis concernant l EHQ dans du graphène exfolié et les premiers tests sur une bicouche. Ils confirment le potentiel de l EHQ dans le graphène pour une application en métrologie.The quantum Hall effect (QHE) observed in two dimensional electron gases (2DEGs) at low temperature and under high magnetic induction, has revolutionized the resistance metrology because it leads to a universal and very reproducible quantum resistance standard only dependent on e and h (respectively the electron charge and Planck's constant). One of the metrologists' missions is to develop standards with improved performances and to notably make them more practical, working for example at higher temperature or lower magnetic induction. In this context, graphene physics could be very interesting for metrological applications. Monolayer graphene is a one atom thick layer of carbon atoms condensed in a honeycomb lattice. A bilayer graphene consists in two stacked monolayers. Larger energy spacings between the first Landau Levels in monolayer and in bilayer than in GaAs make the QHE in graphene more robust and give hope that more practical standards could be developed. During the PhD, we have set a protocol up in order to fabricate exfoliated graphene based Hall bars, including location with an optical microscope, e-beam lithography, metallization, plasma etching Backgated using oxidized silicon wafers the devices were designed to fulfill at best the metrological requirements (large conduction channel, well defined voltage probes ). At low temperature, the typical charge carrier residual doping obtained after the annealing process was 3-4x1011 cm-2. Mobilities were close to 3000 cm2/(V.s) and 4000 cm2/(V.s) respectively for the monolayer and the bilayer based device both for holes and electrons. Mesoscopic transport was characterized at low temperature by weak localization and universal conductance fluctuations (UCF) measurements. The phase coherence length deduced was about 0.5 m below 1.5 K. The resistance of the contacts, measured in the QHE regime, appeared to be rather low (typically few ohms). The QHE was investigated in details at low temperature (300 mK 0) it is possible to demonstrate an agreement within an uncertainty of 3 parts in 107. That accuracy is essentially limited by the small size, and the poor homogeneity of the carrier density of the graphene electronic systems, both acting for a very reduced breakdown current of the QHE (1-2 A). Nevertheless these results are the most accurate tests of the QHE performed in exfoliated graphene and the first universality test of the QHE with bilayer graphene. They confirm the potential of the QHE in graphene for the metrological application.PARIS11-SCD-Bib. électronique (914719901) / SudocSudocFranceF
    corecore